Before starting to install a pneumatic solenoid valve, it is important to read the instructions or the relevant user manual carefully to ensure that the five-way solenoid valve is suitable for the desired application.
Precautions During Installation
Although the Pneumatic Solenoid Valve can be installed in any direction, due to the vibration of devices or condensate, oil and other liquids may flow into the solenoid coil, which will cause the solenoid valve to be poor, Please take care during installation:

1, Avoid the influence of vibration on the sliding column of pneumatic solenoid valve,During installation, the vibration direction may form a right angle to the action direction (axial direction) of the solenoid valve slide column

Single coil solenoid valve: it is better to install the coil upward or horizontally

Double coil solenoid valve: it is better to install the coil horizontally

2, To prevent condensate or oil from flowing into the solenoid valve coil, it is better to install the coil upward or horizontally

 3,  Blow away the miscellanies such as dust, oil pollution and chips in the pipeline to avoid influencing the action and damage of solenoid valves


 4,  Internal pilot type pneumatic solenoid valve, can not assemble the throttle valve at the inlet, to prevent the pressure drop too large during reversing from malfunction


 5, The pneumatic solenoid valve shall be installed as close to the cylinder as possible: First: reduce air consumption; second: respond quickly


6, Please make sure completely insert the air pipe to the end and confirming that the air pipe cannot be pulled out then use it


7, Although our solenoid coil is 100% ED, long-term energized will cause overheating, deterioration of insulation and loss of energy. In case of continuous power on for a long time, the solenoid valve with memory function shall be used to shorten the power on time, extend the service life of the coil and save energy consumption


8, Do not use the manual button when the solenoid valve is energized


9, The operating voltage, Action frequency, working pressure and working temperature range of the solenoid valve shall be within the specified range, so as to avoid the poor action of the solenoid valve or burning the coil


10, Solenoid valve is installed in the control cabinet. If it is energized for a long time, attention should be paid to the ventilation and heat dissipation of the control cabinet to ensure that the temperature in the cabinet is within the solenoid valve's working temperature range


 11,  In order to prevent the two coils of the dual electrical pneumatic solenoid valve from being energized at the same time, the control circuit should be designed with chain protection


12, The main valve’s breathing hole and the pilot valve’s exhaust port must not be blocked or the exhaust hole is not smooth


13, DC type solenoid valve has polar indicator lights, pay attention to the positive and negative poles when wiring. Connect “1” to the positive pole, and “2” to the negative pole. If connection is inversed, the indication lights will not shine but valves can still work.

Conclusion
Buy cheap 5-port pneumatic solenoid valves for your automated system on PFCautomations.com. We can provide sy series, 5v series, 4a series. You are welcome to come to consult!
1 Comments
Leave a Comment
Your email address will not be published. Required fields are marked *
Submit Comment
People who viewed this item also viewed
Contact Us Now
China Fluid Control Valve Manufacturers and Suppliers - PFC Pneumatic
Shangtian industry zone, Ningbo 315511,China
You can trust us
We are a professional Manufacturer in China, and we are constantly innovating so that our customers can have better products and services.
Contact Us
© 2024 PFC        SiteMap.html    SiteMap.xml    Terms of Service      Privacy Policy
Marketing Support by Globalsir
Enter your inquiry details, We will reply you in 24 hours.
Name can't be empty
E-mail can't be empty
Company can't be empty
Phone can't be empty
Products can't be empty
Message can't be empty
Verification code error
code
Clear